The autoclave should be placed in a high-pressure operation room that meets the requirements of explosion-proof. When multiple autoclaves are installed, they should be placed separately. Each two should be separated by a reliable explosion-proof high wall. Each operation room has direct access to the outdoor. Or the exit of the channel, when there is explosive medium, the location of the equipment should be ensured and the ventilation is better.
Positive and negative nut joint
At the joint of the positive and negative nuts, only the positive and negative nuts should be rotated. The circular arc surfaces of the two sides should not be rotated relative to each other. For all the threaded couplings, oil or oil-adjusted graphite should be applied to avoid seizure.
Use of valves
Needle type valve adopts line seal, only need to gently rotate the valve needle, press the cover tightly, and the good sealing effect can be achieved. Excessive force is strictly prohibited, so as not to damage the sealing surface.
Fixed contact check
Check if the movable parts and fixed contacts on the panel and rear panel are normal, pull out the upper cover, check if the connector is loose, and if there is any damage or rust caused by improper transportation and storage.https://www.syhgzben.com/